MIL-PRF-24236/1P
Inches
mm
Inches
mm
Inches
mm
Inches
mm
0.005
0.13
0.15
3.81
0.41
10.41
0.65
16.51
0.007
0.18
0.18
4.57
0.45
11.43
0.68
17.27
0.01
0.25
0.187
4.75
0.468
11.89
0.7
17.78
0.015
0.38
0.19
4.83
0.481
12.22
0.74
18.8
0.016
0.4
0.22
5.59
0.5
12.7
0.76
19.3
0.02
0.51
0.23
5.84
0.53
13.46
0.79
20.07
0.021
0.53
0.243
6.17
0.531
13.49
0.875
22.23
0.045
1.14
0.26
6.6
0.54
13.72
0.88
22.35
0.05
1.27
0.28
7.11
0.55
13.97
0.924
23.47
0.07
1.78
0.3
7.62
0.562
14.28
0.937
23.8
0.071
1.8
0.325
8.25
0.587
14.91
0.956
24.28
0.117
2.97
0.34
8.64
0.59
14.99
1.16
29.46
0.125
3.18
0.375
9.53
0.6
15.24
1.26
32.00
0.138
3.51
0.395
10.03
0.625
15.88
1.28
32.51
0.14
3.56
0.64
16.26
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for general information only.
3. Unless otherwise specified, tolerance is ±.015 (0.38 mm).
4. Exact shape of switch and terminals are optional provided dimensions specified are not exceeded.
5. This dimension not to exceed extended envelope of the switch.
6. Mounting brackets are not to be furnished.
7. Configurations D, D1, E, E1, F, and F1 formerly covered by this specification sheet are now covered
by MIL-PRF-24236/20.
8. Configurations A1, A2, and A3 use basic switches of configuration A.
Configurations B1, B2, and B3 use basic switches of configuration B.
FIGURE 1. Switches, thermostatic, (bimetallic), subminiature, type I, hermetically sealed - Continued.
11