MIL-PRF-22885/103B
Qualification inspection:
Group submission: Table II applies provided that similar products are qualified to MIL-PRF-22885/56 and
MIL-PRF-22885/85.
Quality conformance inspection:
Group B inspection:
EMI/RFI shielding: Only positive grounding test need be performed.
Group A inspection: Do not exceed 6 V dc or peak ac, 10 milliamperes during group A inspection.
TABLE II. Qualification inspection (group inspection).
Qualification inspection table
Additional
Extent of
of MIL-PRF-22885
inspections
approval
Switch
Group
Number of samples
I
All samples
II
4
M22885/103-044
III
2
2/ 4/
VI 1/
2
VII
2
6/ 7/
All
All samples
I
II
M22885/103-031
4
VIII
3/ 4/
2 each color 5/
1/ Resistive dc loads only (sea level and altitude).
2/ Units shall be equipped with M22885/104-10 pushbuttons and 4 MIL-DTL-6363/6-4
lamps.
3/ Units shall be equipped with M22885/104-7 pushbuttons and 4 MIL-DTL-6363/6-4
lamps.
4/ Legend shall consist of 2 lines of characters which utilize at least ¾ of the maximum
legend area.
5/ Two pushbuttons of each color may be installed on housings submitted to the
inspections of group II.
6/ Two sample units each of styles S, W, L, A and I assemblies shall be inspected for
visual and mechanical examination and operating characteristics.
7/ Two sample units each of style I indicator assemblies shall be inspected for
solderability, resistance to soldering heat, and lamp contact resistance.