MIL-DTL-9419G
FIGURE 1. Suggested fixture, impact test.
4.7.10 Dielectric withstanding voltage (see 3.5.8). Switches shall be tested in accordance with method
301 of MIL-STD-202. The following details and exceptions shall apply:
a. Magnitude of test voltage: 1,000 volts.
b. Nature of potential: AC root mean square (rms).
c. Duration of application of test voltage: For group A inspection, at the option of the contractor, the
test voltage may be applied for period of 5 seconds.
d. Points of application of test voltage: Between all unconnected terminals and between all load
terminals connected together and common with the switch in the off position.
e. Measurements during test: Leakage current.