MIL-PRF-22885/80H
REQUIREMENTS:
Design and construction: See figures 1 through 5.
Complete switch shall consist of:
1 - Plug-in switch/indicator assembly (see figure 3).
1 - Housing.
4 - Lamps (T-1 ¾ midget-flanged-base). Not included, order separately.
Plug-in switch/indicator assembly shall include:
1 - Switch module.
1 - Lens module: Consists of lens assembly in accordance with MIL-PRF-22885/82, as specified (see table
IV and V), lens retainer (M-22885/82-50 or 58), and lamp capsule assembly with RFI screen and moisture
seal. The lamps and lens assembly shall be capable of being installed or removed from the panel front
without the use of special tools.
Housing shall include:
1 - Terminal block.
1 - Mounting fastener.
Terminals: See figure 5 for available part numbers. Not included, order separately.
Enclosure design: 2 (Dripproof).
Temperature characteristic:
-55°C minimum to +71°C maximum.
+55°C maximum with lamps energized.
Vibration grade: 2 (10-500 Hz).
Operation: A (momentary), B (alternate), H (indicator only).
Color: See table II and MIL-PRF-22885/82.
Display type: W (white until illuminated, then background appears in color specified).
Weight:
Type 1: 3.0 ounces maximum.
Type 2: 3.5 ounces maximum.
Type 3: 2.5 ounces maximum.
Solderability: Not applicable.
Resistance to soldering heat: Not applicable.