MIL-DTL-28788C
percent of the total length of fillet, which is between the standard wrap wire and the terminal, shall be
tangent to the surface of the terminal being tested. There shall be no pinholes, voids, and so forth. A
ragged or interrupted line at the point of tangency between the fillet and the terminal under test shall be
considered a defect. After the test, there shall be no evidence of fracture, loosening of parts, or any other
mechanical failure of the switches.
operating points shall be within the tolerances specified (see 3.1).
3.8.1 Actuation and deactuation. When tested as specified in 4.7.4.1, switches shall actuate and
3.8.2 Proof flow. When tested as specified in 4.7.4.2, switches shall be capable of passing a
minimum proof flow with a maximum differential pressure (pressure drop) as specified (see 3.1 and 6.1).
3.8.3 Differential pressure (pressure drop through switches). When tested as specified in 4.7.4.3,
calibration and proof flow, the total pressure drop across the switch shall not exceed the specified values
3.8.4 Proof pressure. When tested as specified in 4.7.4.4, switches shall show no evidence of
leakage. Unless otherwise specified (see 3.1), the proof pressure shall be at least 150 percent of the
maximum operating pressure. The actuation and deactuation flow rate, measured before and after the
3.9 Transfer time. When switches are tested as specified in 4.7.5, the contacts of a pole shall
transfer within 5 milliseconds on both increasing and decreasing flow within the operating tolerances
3.10 Coincidence of operating points (applicable to multipole switches only). When switches are
tested as specified in 4.7.6, all poles shall transfer within a total operating time of 10 milliseconds on both
3.11 High temperature. When switches are tested as specified in 4.7.7, there shall be no evidence
of malfunction, internal leakage, deterioration, combustion, or any other damage that may adversely affect
the operation of the switch.
3.12 Low temperature. When switches are tested as specified in 4.7.8, there shall be no evidence
of malfunction, internal leakage, deterioration, combustion, or any other damage that may adversely affect
the operation of the switch.
the terminals shall not break, loosen, crack, or affect the operation of the switch.
there shall be no loosening, rotation, distention, short circuiting, open circuiting, or other damage of any
portion of the connector-switch interface or switch itself.