MIL-PRF-22885/91C
Vibration: Grade 2 (10-500 Hz). During the entire vibration schedule, the specified supply voltage shall be applied
to the input terminal and the output circuit shall be monitored for change in state. The output circuit shall show no
evidence of change of state in excess of 10 microseconds.
Shock (specified pulse): MIL-STD-202, method 213, test condition A (50 G's). During the test, the specified
supply voltage shall be applied to the input terminal and the output circuit shall be monitored. The output circuit
shall show no evidence of change of state in excess of 10 microseconds.
TABLE III. Electrical characteristics.
Parameter
Min.
Nom.
Max.
Conditions
Integrated
circuit
type
Electrical characteristic code A
Supply
4.5 V dc
5.0 V dc
5.5 V dc
0 C to 55 C
voltage
---
---
.0040A
Circuit released
Supply
excludes load current
current
supply voltage 4.5 to 5.5 V dc
released
---
---
.009A
Circuit operated
Supply
excludes load current
current
supply voltage 4.5 to 5.5 V dc
released
---
---
+ .4 V dc
Circuit operated
Output
load current = .008 A
voltage
supply voltage 4.5 to 5.5 V dc
operated
5 V dc
Output
---
---
20.0 micro-
Output terminated to +10.0 V dc
sinking
leakage
amperes
supply voltage 4.5 to 5.5 V dc
circuit released
Fall time
---
---
1.0 micro-
Supply voltage 4.5 to 5.5 V dc
amperes
90% to 10% of the output
voltage swing when sinking
.008A (see figure 9)
Rise time
---
---
1.0 micro-
Supply voltage 4.5 to 5.5 V dc
10% to 90% of the output
second
voltage swing when sinking
.008A (see figure 9)
Absolute maximum ratings (beyond which damage may occur)
Ambient
---
Storage
-40 C
-65 C
voltage
---
Operating
0C
-55 C
Supply
-.5 V dc
---
+7.0 V dc
0 C to -55 C
voltage
5 V dc
-.5 V dc
---
+15.0 V dc
Circuit released
Externally
sinking
applied
output
voltage
---
---
.020 A
Circuit operated.
Sinking
output
current
13