MIL-PRF-22885/56H
TABLE III. Qualification inspection (group submission).
Qualification inspection
Extent
table X of MIL-PRF-22885
Switch
of
approval
Group
Number of sample units
I
24 1/
II
4 2/
III
2 from group I 4/
M22885/56-077
IV
2 from group I 4/
4PDT alternate
V
2 from group I 4/
All
VI
12 2/ from group I 4/
VII
2 from group I 4/
VIII
2 each color 3/
M22885/56-005
I
4
4PDT momentary
II
4 from group 1
1/ Two samples shall be subjected to the RFI test of this specification sheet.
2/ Electrical endurance at reduced barometric pressure test applicable.
3/ Two lenses of each color may be installed on samples submitted to the tests of groups II thru VII for
use in group VIII tests.
4/ Seal test to be performed groups II and III only.
TABLE IV. Dash numbers, design and operating characteristics.
Circuit
Lens code
RFI
Dash number 1/
Lens height
description
2/
shielded
-001 3/
4 PDT momentary
-
extended
no
-002 3/
4 PDT alternate
-
extended
no
-003 3/
4 PDT momentary
-
flush
no
-004 3/
4 PDT alternate
-
flush
no
-005(XXXX)
4 PDT momentary
A
extended
no
-006(XXX)
4 PDT momentary
B
extended
no
-007(XX)
4 PDT momentary
C
extended
no
-008(X)
4 PDT momentary
D
extended
no
-009(XXX)
4 PDT momentary
E
extended
no
-010(XX)
4 PDT momentary
F
extended
no
-011(XXX)
4 PDT momentary
G
extended
no
-012(XXX)
4 PDT momentary
H
extended
no
-013(XXXX)
4 PDT alternate
A
extended
no
-014(XXX)
4 PDT alternate
B
extended
no
-015(XX)
4 PDT alternate
C
extended
no
-016(X)
4 PDT alternate
D
extended
no
-017(XXX)
4 PDT alternate
E
extended
no
-018(XX)
4 PDT alternate
F
extended
no
-019(XXX)
4 PDT alternate
G
extended
no
-020(XXX)
4 PDT alternate
H
extended
no
-021(XXXX)
2 PDT momentary
A
extended
no
-022(XXX)
2 PDT momentary
B
extended
no
-023(XX)
2 PDT momentary
C
extended
no
-024(X)
2 PDT momentary
D
extended
no
See footnotes at end of table.