MIL-DTL-9395/5E
REQUIREMENTS:
Dimensions and electrical schematic: See figure 1.
Weight: 0.2 pound maximum.
Calibration: See tables I, II, III, and IV.
Proof pressure: 4,500 lbf/in2.
System pressure: 3,000 lbf/in2.
Burst pressure: 7,500 lbf/in2.
Electrical ratings:
Operating voltage: 28 Vdc.
Current rating: 5 amperes resistive.
2.5 amperes inductive.
Seal:
Electrical chamber: Hermetic.
Pressure chamber: Hermetic.
Reference chamber: Sealed or unsealed.
Pressure port: See figure 1.
Media: Hydraulic fluid IAW MIL-PRF-6083 or MIL-PRF-83282.
High temperature (operating and nonoperating): B (+275°F).
Low temperature (operating and nonoperating): D (-65°F).
Altitude: C (70,000 feet).
Shock: C (100 G).
Vibration: S (test condition D, method 204 of MIL-STD-202).
Life (mechanical): A (100,00 cycles).
Life (electrical): C (50,000 cycles).
Acceleration: C (8 G).
Pulsation amplitude: C (5 percent).
Pulsation frequency: D (500 ±50 Hz).
Pressure rise: F (500,00 lbf/in2).
Dielectric withstanding voltage (at reduced barometric pressure): Applicable.
Terminal strength (wire-lead terminals): Method 211 of MIL-STD-202, test condition A, except apply 25
pounds for 5 minutes in a direction straight away from the switch.
QUALIFICATION:
Single submission: Restricted to switch submitted.
Group submission: See table V.