MIL-DTL-9395/2D
TABLE I. Dash number and pressure switch settings.
Pressure switch settings
Minimum
Decreasing
dead band
Configuration
Dash
Increasing
2
2
2
no.
lbf/in
lbf/in
lbf/in
1,200 ±250
01
By 700
100
1
2,900 ±150
02
By 2,400
200
1
At 1,700 ±100
03
By 2,000
---
2
At 2,600 ±100
04
By 2,875
---
2
NOTES
Referenced documents. In addition to MIL-DTL-9395, this specification sheet references the following
documents.
MIL-PRF-6083
MIL-PRF-46170
MIL-PRF-83282
MIL-PRF-87257
MS3456
MIL-STD-202
SAE-AS5202
Custodians:
Preparing activity:
Army - CR
DLA - CC
Navy - EC
Air Force - 11
(Project 5930-1782)
DLA - CC
Review activities:
Army - AV
Navy - AS, MC
Air Force - 99
4