MIL-DTL-9395/2D
REQUIREMENTS:
Dimensions, configuration, and electrical schematic: See figure 1.
Weight: 9 ounces maximum.
Calibration:
See table I.
2
Proof pressure: 4,500 lbf/in .
Vent port proof pressure (configuration 1 only): Leakage from the return vent port shall not exceed 1
drop per minute with system pressure applied to pressure port.
2
System pressure: 3,000 lbf/in .
2
Burst pressure: 7,500 lbf/in .
Electrical ratings:
Operating voltage - 28 Vdc.
Current rating -
4 amperes resistive.
2 amperes inductive (L/R ratio = .026)
Seal:
Electrical chamber: Unsealed.
Pressure chamber: Water tight.
Reference chamber:
Unsealed.
Media: Hydraulic fluid per MIL-PRF-6083, MIL-PRF-46170, MIL-PRF-83282 or MIL-PRF-87257.
High temperature (operating and nonoperating): B (+275°F).
Low temperature (operating and nonoperating): D (-65°F).
Altitude: C (70,000 feet).
Shock: C (100 G).
Vibration: S (test condition D, method 204 of MIL-STD-202, except 10 - 2,000 Hz, 20 G).
Life:
Mechanical - A (100,000 cycles).
Electrical - A (100,000 cycles).
Acceleration: B (4 G).
Pulsation amplitude: C (5 percent).
Pulsation frequency: D (500 ±50 Hz).
2
Pressure rise: F (500,000 lbf/in ).
Dielectric withstanding voltage (at reduced barometric pressure): Applicable.
Connector torque: Applicable.
Part number: M9395/2- (dash number from table I).
3