MIL-DTL-3950/14A
TABLE I. Circuit code and electrical ratings for one pole switches.
Current
Current
Circuit with rocker in
capacity (amperes)
capacity (amperes)
Circuit
28 volts dc
115 volts, 60 and
code
400 hertz ac
number
Inductive
Lamp-
Resistive
Inductive
Resistive
Center
Opposite
Lamp-
Identification tab
circuit
load
circuit
circuit
identification
load
circuit
side
circuit
tab side
circuit
-21
1-2 ON
OFF
2-3 ON
-22
OFF
NONE
2-3 ON
5
20
15
3
15
10
-23
1-2 ON
NONE
2-3 ON
-24
NONE
OFF
2-3 ON
-25
NONE
MOM OFF
2-3 ON
-26
1-2 MOM ON
NONE
2-3 ON
-27
1-2 MOM ON
OFF
2-3 MOM ON
-28
1-2 MOM ON
OFF
NONE
4
15
10
2
15
7
-29
MOM OFF
NONE
2-3 ON
-30
1-2 MOM ON
NONE
OFF
-31
1-2 MOM ON
OFF
2-3 ON
-32
NONE
ON 1-2
2-3 MOM ON
-33
NONE
ON 1-2
ON
5
20
15
3
15
10
TABLE II. Circuit code and electrical ratings for two pole switches.
Current
Current
Circuit with rocker in
capacity (amperes)
capacity (amperes)
28 volts dc
Circuit
115 volts, 60 and
code
400 hertz ac
number
Identification tab
Center
Opposite
Lamp-
Resistive
Inductive
Lamp-
Resistive
Inductive
side
identification
load
circuit
circuit
load
circuit
circuit
tab side
circuit
circuit
-21
1-2 ON 4-5
OFF
2-3 ON 5-6
-22
OFF
NONE
2-3 ON 5-6
7
20
15
4
15
15
-23
1-2 ON 4-5
NONE
2-3 ON 5-6
-24
NONE
OFF
2-3 ON 5-6
-25
NONE
MOM OFF
2-3 ON 5-6
-26
1-2 MOM ON 4-5
NONE
2-3 ON 5-6
-27
1-2 MOM ON 4-5
OFF
2-3 MOM ON 5-6
-28
1-2 MOM ON 4-5
OFF
NONE
5
18
10
2
11
8
-29
MOM OFF
NONE
2-3 ON 5-6
-30
1-2 MOM ON 4-5
NONE
OFF
-31
1-2 MOM ON 4-5
OFF
2-3 ON 5-6
-32
NONE
1-2 on 4-5
2-3 MOM ON 5-6
-33
NONE
1-2 ON 4-5
2-3 ON 5-6
7
20
15
4
15
215
-34
1-2 ON 4-5
1-2 ON 4-5
2-3 ON 5-6
5