MS35059K
TABLE II: Detail Requirements
MS Part No. |
Circuit with toggle lever in |
Current Capacity (amperes per pole) |
|||||||||||||||
Direct Current |
Alternating Current 400 Hertz |
Alternating current 60 Hertz |
|||||||||||||||
Keying side |
Center |
Opposite keying side |
Lamp- load circuit |
Resistive circuit |
Inductive circuit |
Lamp load circuit |
Resistive circuit |
Inductive circuit |
Resistive circuit |
Inductive circuit |
Lamp load circuit |
||||||
28 volts |
28 Volts |
125 Volts |
250 Volts |
28 Volts |
125 Volts |
250 Volts |
115 Volts |
115 Volts |
115 volts |
115 volts |
220 volts |
115 Volts |
115 Volts |
||||
MS35059- 21 |
On |
Off |
On |
7 |
20 |
---- |
--- |
15 |
------ |
----- |
4 |
20 |
15 |
20 |
----- |
--- |
---- |
MS35059- 22 |
Off |
None |
On |
||||||||||||||
MS35059- 23 |
On |
None |
On |
||||||||||||||
MS35059- 24 |
None |
Off |
On |
||||||||||||||
MS35059- 25 |
None |
Mom- Off |
On |
5 |
18 |
------ |
-- |
10 |
------ |
----- |
2 |
11 |
8 |
11 |
----- |
---- |
------- |
MS35059- 26 |
Mom- On |
None |
On |
||||||||||||||
MS35059- 27 |
Mom- On |
Off |
Mom-On |
||||||||||||||
MS35059- 28 |
Mom-on |
Off |
None |
||||||||||||||
MS35059- 29 |
Mom- Off |
None |
On |
||||||||||||||
MS35059- 30 |
Mom-on |
None |
Off |
||||||||||||||
MS35059- 31 |
Mom-on |
Off |
On |
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business