MS27782D
TABLE I Detail Requirements
MS Part Number |
Available Locking combinations |
Circuit with toggle lever in |
Current capacity (amperes) 28 volts dc |
Current capacity (amperes) 115 volts, 60 and 400 hertz ac |
||||||
Keying side |
Center |
Opposite Keying side |
Lamp Load circuit |
Resistive circuit |
Inductive circuit |
Lamp Load circuit |
Resistive circuit |
Inductive circuit |
||
MS27782-1 |
ALL |
1-2 ON 4-5 |
1-2 ON 5-6 |
2-3 ON 5-6 |
7 |
20 |
15 |
4 |
15 |
15 |
MS27782-2 |
E,F,K,L,M,N |
MOM 1-2 ON 4-5 |
1-2 ON 5-6 |
2-3 ON 5-6 |
5 |
18 |
10 |
2 |
11 |
8 |
MS27782-3 |
E,L,N |
MOM 1-2 ON 4-5 |
1-2 ON 5-6 |
MOM 2-3 ON 5-6 |
||||||
MS27782-21 |
ALL |
1-2 ON 4-5 |
OFF |
2-3 ON 5-6 |
7 |
20 |
15 |
4 |
15 |
15 |
MS27782-22 |
D,F,G |
OFF |
NONE |
2-3 ON 5-6 |
||||||
MS27782-23 |
D,F,G |
1-2 ON 4-5 |
NONE |
2-3 NO 5-6 |
||||||
MS27782-24 |
E,F,K,M |
NONE |
OFF |
2-3 ON 5-6 |
5 |
18 |
10 |
2 |
11 |
8 |
MS27785-25 |
F |
NONE |
MOM. OFF |
2-3 ON 5-6 |
||||||
MS27782-26 |
F |
MOM 1-2 ON 4-5 |
NONE |
MOM 2-3 ON 5-6 |
||||||
MS27782-27 |
E,L,N |
MOM 1-2 ON 4-5 |
OFF |
|||||||
MS27782-28 |
E |
MOM OFFf |
OFF |
NONE |
||||||
MS27782-29 |
F |
MOM 1-2 ON 4-5 |
NONE |
2-3 ON 5-6 |
||||||
MS27782-30 |
F |
MOM 1-2 ON 4-5 |
NONE |
OFF |
||||||
MS27782-31 |
E,F,K,L,M,N |
MOM 1-2 ON 4-5 |
OFF |
2-3 ON 5-6 |
||||||
MS27782-32 |
E |
NONE |
1-2 ON 4-5 |
MOM 2-3 ON 5-6 |
||||||
MS27782-33 |
E,F,K,M |
NONE |
1-2 ON 4-5 |
2-3 ON 5-6 |
7 |
20 |
15 |
4 |
15 |
15 |
Test Requirements
Test shall be performed in accordance with MIL-DTL-3950 except
a) During all tests. Switches shall be fully wired with appropriate wire and terminal contacts.
b) Contact voltage drop- the contact drop with two terminals and the switch contact in series shall not exceed 8 millivolts measured from one wire contact through the contacts to the other wire contacts.
4
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business