MS27782D
REQUIREMENTS
Sealing plugs may be used in nonfunctional grommet holes.
Sealing grommet shall seal on a smooth wore insulation of .06 (1.73 mm) to 1.03 (2.62 MM) diameters
The terminal end of switch shall be color coded blue to indicate contact size
Direction of internal mechanism movement is opposite to the direction of the toggle movement
Maximum weight is .137 pound.
The locking means at the top of the toggle bushing shall be capable of withstanding a torque of 20 inch- pounds applied in both directions immediately following the humidity test.
Locking arrangement Positive locking shall be accomplished and shall prevent motion of the toggle lever until the locking mechanism shall be 3 to 5 pounds
Direction of internal mechanism movement is opposite to the direction of the toggle movement. Electrical rating: See table I