MS27781D
TABLE I: Detail Requirements
MS Part No. |
Available Locking combinations |
Circuit with Toggle Lever In |
Current capacity (amperes) 28 volts DC |
Current capacity(amperes) 115 volts, 60 and 400 Hertz AC |
||||||
Keying side |
Center |
Opposite keying side |
Lamp Load circuit |
Resistive circuit |
Inductive circuit |
Lamp- Load circuit |
Resistive circuit |
Inductive circuit |
||
MS27781-21 |
ALL |
1-2 ON |
OFF |
2-3 ON |
5 |
20 |
15 |
3 |
15 |
10 |
MS27781-22 |
D, F, G |
OFF |
NONE |
2-3 ON |
||||||
MS27781-23 |
D,F,G |
1-2 ON |
NONE |
2-3 ON |
||||||
MS27781-24 |
E,F,K,M |
NONE |
OFF |
2-3 ON |
||||||
MS27781-25 |
F |
NONE |
MOM OFF |
2-3 ON |
4 |
15 |
10 |
2 |
15 |
7 |
MS27781-26 |
F |
1-2 MOM. ON |
NONE |
2-3 ON |
||||||
MS27781-27 |
E,L,N |
1-2 MOM. ON |
OFF |
2-3 MOM ON |
||||||
MS27781-28 |
E |
1-2 MOM ON |
OFF |
NONE |
||||||
MS27781-29 |
F |
MOM OFF |
NONE |
2-3 ON |
||||||
MS27781-30 |
F |
1-2 MOM OFF |
NONE |
OFF |
||||||
MS27781-31 |
E,F,K,L,M,N |
1-2 MOM ON |
OFF |
2-3 ON |
||||||
MS27781-32 |
E |
NONE |
ON 1-2 |
2-3 MOM ON |
||||||
MS27781-33 |
E,F,K,M |
NONE |
ON 1-2 |
2-3 ON |
5 |
20 |
15 |
3 |
15 |
10 |
Test Requirements
a) During all tests. Switches shall be fully wired with appropriate wire and terminal contacts.
b) Contact voltage drop- the contact drop with two terminals and the switch contact in series shall not exceed 8 millivolts measured from one wire contact through the contacts to the other wire contacts.
4