MS27708J
REQUIREMENTS:
Design and configuration: See figure 1. Material:
Actuating caps: Actuating caps shall be polycarbonate in accordance with ASTM D3935, color-black. Marking:
Terminal identification letters shall be molded or engraved adjacent to designated terminal and must be permanent, legible, and clearly visible.
Arrows on top surface of housing shall indicate the direction of travel. They shall be depressed and white filled. Electrical endurance:
Inductive loads: MS27708-4:
115 V ac, 400 Hz:
5 amperes, 250,000 cycles.
28 V dc:
20 amperes, 150,000 cycles.
5 amperes, 250,000 cycles.
Part of Identifying Number (PIN): MS 27708-4.
Supersession data: MS27708-1, MS27708-2, and MS27708-3 are canceled and superseded by MS27708-4.
The margins of this specification are marked with vertical lines to indicate where modifications from this revision were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations.
Referenced documents. In addition to MIL-DTL-9419, this document references the following: ASTM D3935
Custodians: Preparing activity: Army - AV DLA - CC
Navy - AS
Air Force - 85 Project (5930-2011-035) DLA - CC
Review activities: Air Force - 99
NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https://assist.daps.dla.mil/.
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business