MS27708J
Circuit diagram
Arrows indicate contact in the direction of lever travel as viewed from the rear of the switch.
Inches |
mm |
Inches |
mm |
Inches |
mm |
.005 .015 .016 .020 .078 .094 |
0.13 0.38 0.41 0.51 1.98 2.39 |
.180 .200 .218 .275 .455 .688 |
4.57 5.08 5.54 6.99 11.56 17.48 |
.937 .995 1.156 1.215 1.255 |
23.80 25.27 29.36 30.86 31.88 |
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for general information only.
3. Unless otherwise specified, tolerance is ± .010 (0.25 mm).
4. Terminal end of switch shall have no external moving parts and shall have barriers between terminals.
5. Terminal length optional but must not extend beyond common terminal or diameter of switch.
6. The design of the button and shaft on MS27708-4 shall provide for absolute protection from electrical shock from live shaft and attaching screw. A button shield of insulating material may be utilized for this purpose,
as shown in figure 1. Other button and shaft designs may be used to assure this protection, however, all such designs must have prior approval from the qualifying activity. The use of epoxy adhesive alone as an electrical insulation material is not permitted.
FIGURE 1. Dimensions and configurations - Continued.
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.