MS24660G
TABLE I Detail Requirements.
MS part No. |
Available locking combinations |
Circuit with Toggle Lever In |
Current capacity (amperes) 28 volts DC |
Current capacity(amperes) 115 volts, 60 and 400 Hertz AC |
||||||
Keying side |
Center |
Opposite keying side |
Lamp- Load circuit |
Resistive circuit |
Inductiv e circuit |
Lamp- Load circuit |
Resistive circuit |
Inductive circuit |
||
MS24660-21 |
All |
1-2 7-8 4-5 On 10-11 |
Off |
2-3 8-9 5-6 On 11-12 |
5 |
20 |
12 |
4 |
15 |
15 |
MS24660-22 |
D,F,G |
Off |
None |
2-3 8-9 5-6 On 11-12 |
||||||
MS24660-23 |
D,F,G |
1-2 7-8 4-5 On 10-11 |
None |
2-3 8-9 5-6 On 11-12 |
||||||
MS24660-24 |
E,F,K,M |
None |
Off |
2-3 8-9 5-6 On 11-12 |
||||||
MS24660-25 |
F |
None |
Mom. Off |
2-3 8-9 5-6 On 11-12 |
4 |
18 |
10 |
2 |
11 |
8 |
MS24660-26 |
F |
1-2 Mom 7-8 4-5 On 10-11 |
None |
2-3 8-9 5-6 On 11-12 |
||||||
MS24660-27 |
E,L,N |
1-2 Mom 7-8 4-5 On 10-11 |
Off |
2-3 Mom 8-9 5-6 On 11-12 |
||||||
MS24660-28 |
E |
1-2 Mom 7-8 4-5 On 10-11 |
Off |
None |
||||||
MS24660-29 |
F |
Mom. Off |
None |
2-3 8-9 5-6 On 11-12 |
||||||
MS24660-30 |
F |
1-2 Mom 7-8 4-5 On 10-11 |
None |
Off |
||||||
MS24660-31 |
E,F,K,L,M,N |
1-2 Mom 7-8 4-5 On 10-11 |
Off |
2-3 8-9 5-6 On 11-12 |
||||||
MS24660-32 |
E |
None |
1-2 7-8 4-5 On 10-11 |
2-3 Mom. 8-9 5-6 On 11-12 |
||||||
MS24660-33 |
E,F,K,M |
None |
1-2 7-8 4-5 On 10-11 |
2-3 8-9 5-6 On 11-12 |
5 |
20 |
12 |
4 |
15 |
15 |
4
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business