MS24660G
Inches |
mm |
Inches |
mm |
.005 |
0.13 |
.38 |
9.7 |
.008 |
0.20 |
.42 |
10.7 |
.012 |
0.30 |
.432 |
10.97 |
.020 |
0.38 |
.47 |
11.9 |
.060 |
0.51 |
1.05 |
26.67 |
.076 |
1.93 |
1.10 |
27.94 |
.130 |
2.29 |
1.140 |
28.96 |
.25 |
6.4 |
1.340 |
34.04 |
.37 |
9.4 |
1.370 |
34.80 |
1.660 |
42.16 |
NOTES:
1. Dimensions are inches.
2. Metric equivalents are given for general information only.
3. Unless otherwise specified, tolerance is ± .020 (0.51 mm) for two place decimals and ± .005 (0.13 mm) for three place decimals.
4. For hardware and terminal screw detail specifications, see appendix of MIL-DTL-3950.
5. In event of a conflict between the text of this standard and the reference cited herein, the text of this standard shall take precedence.
FIGURE1. Dimensions and configuration - Continued
REQUIREMENTS
All switches on this standard are designed so that the movement of the switch mechanism is opposite to that of the toggle lever.
Locking arrangement Positive locking shall be accomplished and shall prevent motion of the toggle lever until the locking mechanism is manually released.
The force required to release the locking mechanism shall be 3 to 5 pounds.
The locking means at the top of the toggle bushing shall be capable of withstanding a torque of 20 inch- pounds applied in both directions immediately following the humidity test.
Part number example MS24660-21A (locking combination 'A'). Maximum weight is .20 pound.
Electrical rating: See table I.
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business