MIL-S-24317/12B
Qualification inspection: At the request of the manufacturer, group C testing may be suspended with the qualifying activity's approval if it can be demonstrated that these test have been performed three consecutive times with zero failures. If the design, material, construction, or processing is changed or if there are any quality problems or failures, or at their discretion the qualifying activity may require resumption of the original testing requirement. Suspension of testing does not relieve the manufacturer from meeting the group C test requirements.
Extent of qualification: The multistation switch/ indicator assembly to be used for qualification inspection shall be the 3-station unit (1 X 3 matrix). Qualification of the 3-station units shall qualify all multistation units up to and including the 20-station unit. The 3-station units shall contain the following items:
Item 1 |
PIN M24317/12-223 |
Description 1 X 3 matrix frame (EMI/RFI shielded, dress bezel) |
Quantity 1 |
2 |
M22885/105-009 |
2 PDT momentary switch module |
1 |
3 |
M22885/105-011 |
4 PDT alternate switch module |
1 |
4 |
M22885/105-003 |
Indicator module |
1 |
5 |
M22885/104-001 |
Pushbutton (color and legend optional) |
3 |
6 |
MIL-DTL-6363/6 |
Lamp, T-1 midget flange base |
12 |
TABLE II. Qualification inspection (group submission).
Assembly |
Qualification inspection table of MIL-DTL-24317 |
Extent of approval |
|
Group |
Number of sample units |
||
1 X 3 Matrix |
I II III 1/ |
8 4 from group I 2 from group II 2/ |
All 3/ |
1/ Dielectric withstanding voltage after salt spray not applicable.
2/ Sample shall be subjected to EMI/RFI test of MIL-PRF-22885/103
3/ Qualification will be extended to each applicable style (S, L, W, C or I) previously qualified to
MIL-PRF-22885/103.
Quality conformance inspection: Group B inspection:
EMI/RFI shielding: Only positive grounding test need to be performed.
Group A inspection: Do not exceed 6 V dc or peak ac, 10 milliamperes during group A inspection.
13
For Parts Inquires call Parts Hangar, Inc (727) 493-0744