MIL-S-24317/128
Shock: Tested in accordance with method 213 of MIL-STD-202, test condition letter A (50 g, half sine).
Terminal Strength:
Common termination system (style C): using crimping tool M22520/1-01 and positioner M22520/1-02 to install connector contact on wire, and insertion/extraction tool M81969/14-02, the crimped wire contact shall be inserted and extracted ten times. The insertion and extraction force shall not exceed 10 pounds. The contact shall again be inserted, and must hold axial load of twenty pounds minimum for 10 seconds. Two terminals shall be tested.
Dielectric withstanding voltage: Current flow shall not exceed 100µA. Sea level: 1,056 V rms.
70,000 ft: 450 V rms.
Torque strength of plunger: Not applicable.
Electrical endurance: See table I for test loads. Low level life test and requirement of MIL-PRF-22885 is applicable. All lamps shall be energized at maximum rated voltage during endurance testing.
TA8LE I. Electrical rating.
Load |
Sea Level and 70,000 ft |
Sea Level |
28 V dc and 115 V ac |
30 millivolts 1/ |
|
Resistive Inductive Lamp |
Amperes 2 1 .75 |
Amperes .01 ---- ---- |
1/ Maximum dc or peck ac. Low level life test and requirement in accordance with
MIL-PRF-22885: 50,000 cycles, operating temperatures -55 ° C to + 85 ° C. Weight, approximate (per station):
Two or four flanges, styles S, W, L, and C: 2 ounces. Dress bezel, styles S, W, L and C: 2.1 ounces.
Two or four flanges, style I: 1.5 ounces. Dress bezel, style I: 1.6 ounces.
EMI/RFI shielding: Requirement and test in accordance with MIL-PRF-22885/103.
Sunlight readability: Requirement and test in accordance with MIL-PRF-22885/104. Part or Identifying Number (PIN): M24317/12 - (dash number from table III)
Qualification inspection: All applicants for qualification approval shall demonstrate that each of their
items conforms to all the requirements specified in the applicable documents, singularly and in combination with all other, previously qualified items, regardless of manufacturer. When similar multistation switches are qualified to MIL-S-24317/9 and similar signal station switches are qualified to MIL-PRF-22885/103, qualification and group C inspection shall be in accordance with table III.
12