MIL-PRF-8805/95J
REQUIREMENTS:
Dimensions and configuration: See figure 1.
Enclosure design: I (unsealed).
Temperature characteristic: 1 (-55°C to +85°C).
Shock: 100 g's (half-sine), MIL-STD-202, method 213, test condition C.
Vibration grade: 2(10 to 2000 Hz, swept sinusoidal, 16 g's peak).
Weight: .020 pound maximum.
Operating characteristics:
Total plunger travel: .093 inch (2.36 mm) minimum.
Operating force: 1.50 ±.75 pounds.
Dielectric withstanding voltage:
Sea level: 1,000 V rms minimum initial and 200 V rms following electrical endurance.
Mechanical endurance: 50,000 cycles.
Low temperature cycling rate: 30 cycles per minute minimum.
Electrical endurance:
Resistive loads: 25,000 cycles;
28 V dc, 1 ampere (sea level);
115 V ac, 60 Hz, 1 ampere (sea level).
Inductive loads: 15,000 cycles:
28 V dc, 1 ampere (sea level);
115 V ac, 60 Hz, 1 ampere (sea level).
Part or Identifying Number (PIN): See table I.
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business