MIL-PRF-8805/80G
Seal test: Only watertight test shall be performed in group A.
Sand and dust test: Applicable.
Icing test:
M8805/80-01: Immersion cycles 3.
M8805/80-02 through M8805/8008: Not applicable
Intermediate current:
M8805/80-01: 100,000 cycles.
M8805/80-02 through M8805/8008: Not applicable.
Mechanical endurance: 100,000 cycles.
Electrical endurance: 25,000 cycles.
Electrical ratings: See table I.
Qualification group submission: See table I I .
Part or Identifying Number (PIN): See table I I I .
TABLE I . Electrical ratings.
28 V dc sea level and 100,000 ft.
Load
-01
-02
-03 through 08
(Amperes)
(Amperes)
(Amperes)
Resistive
5
10
7
Inductive
3
3
4
Motor
4
6
4
TABLE I I . Qualification inspection group submission.
Extent of
Examination or test
Basic switch
Other switch samples
approval
M8805/80-02
M8805/80-04
2 samples each for
each electrical test.
M8805/80-02
M8805/80-03
M8805/80-04
Qualification inspection
M8805/80-01
All
M8805/80-06
table of MIL-PRF-8805
M8805/80-07
1 each shall be submitted
to the following test sequence.
1. Strength of actuator means
2. Vibration
3. Shock
4. Operating characteristics
7
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business