MIL-PRF-8805/74L
Table IV. Qualification.
Basic
Extent of
Inspection
Switch
Other switch samples
approval
M8805/74-040
M8805/74- 035
Qualification inspection
(all sample units)
through 039, -041
table of MIL-PRF-8805,
All
through -046
groups I through VI,
(2 sample units each):
inclusive
Visual and
mechanical inspection
only
Table V. Substitution information for canceled PIN's. 1/
Substitute PIN's
Canceled PIN's
M8805/74-
M8805/74-
035
023
004
036
024
006
037
025
007
038
026
009
039
027
013
040
028
015
041
029
016
042
030
018
043
031
019
044
032
020
045
033
021
046
034
022
1/ The canceled PIN's are no longer procurable.
Substitute, PIN configurations are interchangeable
and are rated at 4 amperes for 25,000 cycles.
Referenced documents. In addition to MIL-PRF-8805, this document references the following:
MS21340
MS25081
NASM35333
SAE-AS22759/9
SAE-AS33201
MIL-STD-202
Marginal notations are not used in this revision to identify changes with respect to the previous issue due
to the extent of the changes.
5