MIL-PRF-8805/74L
Table I . PIN;s and configuration.
PIN 1/
Resistive
Plunger
Type of
Terminals
load rating
seal
actuating
mechanism
M8805/74-035
4 Amps
Wire leads bottom
A
M8805/74-036
4 Amps
None
C
Wire leads bottom
M8805/74-037
4 Amps
A
Wire leads side
M8805/74-038
4 Amps
C
Wire leads side
Wire leads bottom
A
4 Amps
M8805/74-039
Wire leads bottom
Resilient
C
4 Amps
M8805/74-040
Wire leads side
Seal
A
4 Amps
M8805/74-041
Wire leads side
C
4 Amps
M8805/74-042
M8805/74-043
4 Amps
D
Wire leads bottom
M8805/74-044
4 Amps
None
D
Wire leads side
M8805/74-045
4 Amps
Resilient
D
Wire leads bottom
M8805/74-046
4 Amps
Seal
D
Wire leads side
1/ PIN's M8805/74-001 through 034 have been canceled. See Table V for substitution
information.
Table I I . Operating characteristics.
Plunger
Actuating
Releasing
Movement
Pretravel
Overtravel
seal
Force
Force
Differential
Inches
(minimum)
(maximum)
(minimum)
(maximum)
(maximum)
4 ounces
.005 inch (0.13
.010 (0.25 mm)
.125 inch (3.18 mm)
Unsealed
30 ounces
1/
1/
mm)
Resilient
7.0 pounds
1.5 pounds
.005 inch (0.13
.020 (0.51 mm)
.125 inch (3.18 mm)
mm)
1/ At sea level and 70,000 feet.
Table I I I . Electrical ratings.
Sea level and 70,000
Load
feet
(28 V dc)
(amperes)
4
Resistive
1
Inductive
2
Lamp
4