MIL-PRF-8805/56G
TABLE I I I . Qualification inspection (group submission).
Examination or test
Basic switch
Additional sample units
Extent of
assemblies
for combined submission
approval
Group I
MS16106-3 and
MS16106-1
Visual and mechanical examination
MS16106-5
(2 sample units)
Operating characteristics
(12 sample units each)
MS16106-2
(2 sample units)
MS16106-4
(8 sample units)
Group II
Strength of actuating means 1/
Strength of mounting 1/
Thermal shock
(4 sample units each
MS16106-4
Vibration
from group I)
(4 sample units each from
Shock
group I)
Operating characteristics
Dielectric withstanding voltage
Visual and mechanical examination
Group III
Salt spray (corrosion)
(2 sample units each
-----
All
Visual and mechanical examination
from group I)
Group IV
Low temperature operation
(2 sample units only)
Mechanical endurance at low
temperature (2 units) 2/
(4 sample units each
MS16106-4
Mechanical endurance at high
from group I)
(4 sample units each from
temperature (2 units)
group I)
Operating characteristics
Dielectric withstanding voltage
Visual and mechanical examination
Group V
Electrical endurance
(2 sample units each
-----
Resistive load, 115 V ac
from group I)
1/ Two sample units only.
2/ Same sample units as for low temperature operation.
Referenced documents. In addition to MIL-PRF-8805, this document references the following:
MIL-S-8805/27
MIL-STD-202
AN508
Marginal notations are not used in this revision to identify changes with respect to the previous issue due
to the extent of the changes.