MIL-PRF-24236/24E
REQUIREMENTS:
Dimensions and configuration: See figure 1 and table I.
Operating temperature range: -65°F to 400°F.
Class: Class 4, except 80,000 feet and vibration 10 - 2,000 Hz, 10G.
Mounting: See figure 1.
Weight: Not to exceed .025 pound.
Creepage: Applicable.
Operating temperature and tolerance: See table II and table III.
Torque (switch mounting): 15 foot-pounds.
Electrical ratings: See table IV.
Endurance test: See table IV.
Low level: When specified, see PIN information.
QUALIFICATION:
Single submission: Restricted to switch submitted.
Group submission: See table V.
Part or Identifying Number (PIN): Consists of "M" prefix followed by specification sheet number; a dash (-); and a
five- or six-letter code. The five-letter code identifies the configuration (code from table I); high temperature
setting to the nearest 25°F (code from table II); high-temperature setting to the nearest 5°F and applicable
tolerance (code from table III); low-temperature setting to the nearest 25°F (code from table II); and low-
temperature setting to the nearest 5°F and applicable tolerance (code from table III). The six-letter code used in
the following example identifies a switch of configuration A (figure 1) which actuates at 65°F ±6°F and deactuates
at 25°F ±6°F and has low level capabilities.
Note: Refer to table VI to avoid generating a PIN that can not be acquired.
EXAMPLE:
M24236/24-
A
GF EH
L
"M" prefix and specification sheet number
Configuration = code "A" of table I (i.e., configuration A)
High temperature setting = code "G" (75°F)
of table II and code "F" (-10°F ±6°F) of
table III (i.e., 75°F, -10°F, ±6°F = 65°F ±6°F)
Low temperature setting = Code "E" (25°F) of table II and code "H"
(0°F ±6°F) of table III (i.e., 25°F, 0°F, ±6°F = 25°F ±6°F)
Add the letter "L" when low level is required