MIL-DTL-9395/31E
TABLE III. Codes for pressure settings to within
25 lbf/in2 and tolerances.
Unit
Tolerance
(lbf/in2)
0
+25
+50
+75
Code
A
B
C
D
±25
Code
E
F
G
H
±50
Code
J
K
L
M
±75
Code
N
P
Q
R
±100
±150
Code
S
T
U
V
±200
Code
W
X
Y
Z
±300
Code
1
2
3
4
±400
Code
5
6
7
8
Code
9
0
+
-
Min or Max
TABLE IV. Codes for differential pressure settings.
Differential
Differential
value (lbf/in2)
value (lbf/in2)
Code
Code
A
0
M
275
B
25
N
300
C
50
P
325
D
75
Q
350
E
100
R
375
F
125
S
400
G
150
T
425
H
175
U
450
J
200
V
475
K
225
W
500
L
250
QUALIFICATION"
Single submission: Restricted to switch submitted.
Group submission: See table V.
TABLE V. Extent of qualification.
Number of samples
Tests
Qualifies
Part number
required
M9395/31-AADAA
2 each resistive
Complete in
M9395/31-DADAA
2 each resistive
accordance with
ALL
M9395/31-G4ZXV
2 each inductive
qualification
configurations
M9395/31-N4ZXV
2 each inductive
inspection of
MIL-DTL-9395
NOTE:
Design limitations (actuation values and tolerances, deadband and deactuation values and tolerances)
should be coordination with the manufacturer(s) listed on the QPL for this specification sheet before
specifying a particular "M" number. The fact that operating characteristics can be coded does not
necessarily mean that it can be manufactured or acquired.
9
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business