MIL-DTL-9395/27G
REQUIREMENTS:
Dimensions, configuration, and electrical schematic: See figure 1.
Weight: See figure 1.
Calibration: See tables I, II, III, and IV.
Tolerance and maximum differential: See table I.
Proof pressure: 120 lbf/in2
System pressure: 60 lbf/in2
Burst pressure: 800 lbf/in2
Electrical ratings:
Operating voltage: 28 Vdc.
Current rating: 3 amperes resistive.
1 ampere inductive.
Seal:
Electrical chamber: See table II.
Pressure chamber: Hermetic.
Reference chamber: Unsealed.
Electrical connector: See figure 1.
Pressure port: See figure 1.
Media: Dry air, nitrogen, fuel IAW MIL-DTL-5624, or lube oil IAW MIL-PRF-7808, or
hydraulic fluid IAW MIL-PRF-6083.
High temperature (operating and nonoperating): B (275°F).
Low temperature (operating and nonoperating): D (-65°F).
Altitude: C (except 80,000 ft).
Shock: C (100 G).
Vibration: S (test condition C, method 204 of MIL-STD-202, except 10 - 2,000 Hz. 10 G).
Life mechanical: A (100,000 cycles).
Life electrical: C (50,000 cycles).
Acceleration: C (8 G).
Pulsation amplitude: A (0%).
Pulsation frequency: A (0 Hz).
Pressure surge: A (less than 100 lbf/in2).
Dielectric withstanding voltage (at reduced barometric pressure): Applicable at 250 V rms.
Connector torque: Applicable.
Terminal strength: Applicable.