MS27407E
REQUIREMENTS
All switches on this standard are designed so that the movement of the switch mechanism is opposite to that of the toggle lever
Maximum weight is 0.20 pound. Electrical rating: See table I.
TABLE I Detail Requirements.
MS part number |
Circuit with toggle lever in |
Current capacity (amperes) 28 volts DC |
Current capacity (amperes) 115 volts, 60 and 400 hertz ac |
||||||
Keying side |
Center |
Opposite keying side |
Lamp- load circuit |
Resistive circuit |
Inductive circuit |
Lamp- load circuit |
Resistive circuit |
Inductive circuit |
|
MS27407-1 |
1-2 On 4-5 |
2-3 On 4-5 |
2-3 On 5-6 |
7 |
20 |
15 |
4 |
15 |
15 |
MS27407-2 |
Mom. 1-2 On 4-5 |
2-3 On 4-5 |
2-3 On 5-6 |
5 |
18 |
10 |
2 |
11 |
8 |
MS27407-3 |
Mom. 1-2 On 4-5 |
2-3 On 4-5 |
Mom. 2-3 On 5-6 |
||||||
MS27407-4 |
1-2 On 4-5 |
1-2 On 5-6 |
2-3 On 5-6 |
7 |
20 |
15 |
4 |
15 |
15 |
MS27407-5 |
Mom. 1-2 On 4-5 |
1-2 On 5-6 |
2-3 On 5-6 |
5 |
18 |
10 |
2 |
11 |
8 |
MS27407-6 |
Mom. 1-2 On 4-5 |
1-2 On 5-6 |
Mom. 2-3 On 5-6 |
Referenced documents
MIL-DTL-3950
Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes.
Custodians: Preparing activity Army - CR DLA - CC Navy - AS
Air Force - 85 (Project 5930-2011-051) DLA - CC
Review activities
Army - AR, AV, MI Navy - EC, MC
Air Force - 99
NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https://assist.daps.dla.mil/ .
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business