MS25068K
NOTES:
1. All dimensions are in inches.
2. For hardware and terminal screw detail specifications see supplement of MIL-DTL-83731.
3. Unless otherwise specified, tolerance is ± .020 on two place decimals and ± .005 on three place decimals.
4. For design feature purposes, this standard takes precedence over procurement documents referenced herein.
REQUIREMENTS:
FIGURE1. Dimensions and configuration Continued.
All switches on this standard are designed so that the movement of the switch mechanism is opposite to that of the toggle lever.
Maximum weight is 0.16 lbs. Electrical Endurance: 10,000 Cycles.
Mechanical Endurance: 20,000 Cycles.
Electrical rating: See table I.
Referenced documents shall be of the issue in effect on the date of invitation for bid.
Table I Detail Requirements.
MS part No. |
Former Ms Part No. |
Circuit with Toggle Lever In |
Current Capacity (Amperes Per Pole) |
|||||||
Direct current |
Alternating current (400 Hertz) |
|||||||||
Keying side |
Center |
Opposite keying side |
Lamp- Load Circuit |
Resistiv e Circuit |
Inductive Circuit |
Lamp load Circuit |
Resistive Circuit |
Inductive Circuit |
||
28 Volts |
28 volts |
28 Volts |
115 volts |
115 Volts |
115 Volts |
|||||
MS25068-21 |
MS25068-1 |
On |
Off |
On |
5 |
20 |
12 |
4 |
20 |
15 |
MS25068-23 |
MS25068-3 |
None |
||||||||
MS25068-24 |
MS25068- 11 |
None |
Off |
|||||||
MS25068-25 |
MS25068- 13 |
Mom Off |
4 |
18 |
10 |
2 |
11 |
5 |
||
MS25068-26 |
MS25068- 10 |
Mom-On |
None |
|||||||
MS25068-27 |
MS25068-7 |
Off |
Mom-On |
|||||||
MS25068-28 |
MS25068- 12 |
None |
||||||||
MS25068-31 |
MS25068-5 |
On |
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business