MS24655S
TABLE I. Detail requirements. 51
MS dash no. |
Circuits made between terminals as indicated with the toggle lever in these positions: 11 |
Current capacity in amperes |
Life low current level switching 5 mV |
|||||||
Resistive load |
Inductive load |
|||||||||
28 V dc |
115 Volts |
28 V dc |
115 Volts |
|||||||
Opposite locking tab side 41 |
Center position |
Locking tab side 41 |
60 Hz ac |
400 Hz ac |
60 Hz ac |
400 Hz ac |
||||
-211 |
2-3 ON |
OFF |
ON 1-2 |
5 |
2 |
3 |
21 1 |
1 |
2 |
31 25 µA |
-221 |
NONE |
OFF |
||||||||
-231 |
NONE |
ON 1-2 |
||||||||
-241 |
OFF |
NONE |
||||||||
-271 |
MOM-ON 2-3 |
1-2 MOM-ON |
||||||||
-281 |
NONE |
|||||||||
-311 |
ON 2-3 |
|||||||||
-321 61 71 |
NONE |
ON |
11 Direction of movement of internal mechanism is opposite to the direction of the toggle movement.
21 With time constant of .020 ± .002 seconds.
31 Contact resistance not to exceed 50 ohms during life, low current level switching.
41 Nonfunctional terminals shall not be supplied.
51 Part or Identifying Number (PIN) example: For IWTS termination MS number will be concluded by the letter W.
Example: MS24655-211 with IWTS termination will be MS24655-211W.
61 Dielectric withstanding voltage: 1,200 V rms at sea level (center on circuits).
71 Delayed action of the switch toggle lever may cause circuit to close or open before snap action mechanism trips.
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business