MS24614L
TABLE l. Detail requirements.
MS dash no. |
Locking comb. |
Circuit made between terminals as indicated with the toggle lever in these positions: |
||
Environ- mentally sealed |
||||
Opposite keyway side |
Center position |
Keyway side |
||
212 |
A' B' C' D' E |
on 2-3' 5-6' 8-9' 11-12 |
off |
on 1-2' 4-5' 7-8' 10-11 |
222 |
C' E |
none |
off |
|
232 |
on 1-2' 4-5' 7-8' 10-11 |
|||
242 |
J' B |
off |
none |
|
262 |
L |
none |
mom-on 1-2' 4-5' 7-8' 10-11 |
|
272 |
F' H |
mom-no 2-3' 5-6' 8-9' 11-12 |
off |
|
282 |
K |
none |
||
292 |
L |
on 2-3' 5-6' 8-9' 11-12 |
none |
mom-off |
302 |
off |
mom-on 1-2' 4-5' 7-8' 10-11 |
||
312 |
G' K' M' N |
on 2-3' 5-6' 8-9' 11-12 |
off |
1/ See footnote at end of table.
TABLE l. Detail requirements - Continued
MS dash no. |
Current capacity amperes per pole 28 volts dc |
Current capacity amperes per pole 115 volts 400 hertz |
Circuit capacity amperes per pole 115 volts 60 hertz |
||||||
Environ- mental sealed |
Lamp load circuit |
Resis- tive circuit |
lnduc- tive circuit |
Lamp load circuit |
Resis- tive circuit |
lnduc- tive circuit |
Lamp load circuit |
Resis- tive circuit |
lnduc- tive circuit |
212 |
7 |
25 |
15 |
7 |
25 |
15 |
7 |
20 |
15 |
222 |
|||||||||
232 |
|||||||||
242 |
|||||||||
262 |
|||||||||
272 |
|||||||||
282 |
|||||||||
292 |
|||||||||
302 |
|||||||||
312 |
1/ See footnote at end of table.