TABLE l. Detail requirements.
MS dash no. |
Locking comb. |
Circuit made between terminals as indicated with the toggle lever in these positions: |
Current capacity amperes per pole 28 volts dc |
Current capacity amperes per pole 115 volts 100 hertz |
Circuit capacity amperes per pole 115 volts 60 hertz |
||||||||
Lamp load circuit |
Resist- ive circuit |
lnduc- tive circuit |
Lamp load circuit |
Resist- ive circuit |
lnduc- tive circuit |
Lamp load circuit |
Resist- ive circuit |
lnduc- tive circuit |
|||||
Environ- mentally sealed |
|||||||||||||
Opposite keyway side |
Center position |
Keyway side |
|||||||||||
212 |
A, B, C, D, E |
on 2-3 |
off |
on 1-2 |
7 |
25 |
15 |
7 |
25 |
15 |
7 |
20 |
15 |
222 |
C, E |
none |
off |
||||||||||
232 |
on 1-2 |
||||||||||||
242 |
J, B |
off |
none |
||||||||||
262 |
L |
none |
mom-on 1-2 |
||||||||||
272 |
F, H |
mom-on 2-3 |
off |
||||||||||
282 |
K |
none |
|||||||||||
292 |
L |
on 2-3 |
none |
mom-off |
|||||||||
302 |
off |
mom-on 1-2 |
|||||||||||
312 |
G, K, M, N |
on 2-3 |
off |
1/ See footnote at end of table.