MS21357J
Inches |
mm |
Inches |
mm |
Inches |
mm |
.005 .008 .012 .025 .030 .032 |
0.13 0.20 0.30 0.64 0.76 0.81 |
.038 .055 .072 .160 .200 .240 |
0.97 1.40 1.83 4.06 5.08 6.10 |
.364 .432 .438 .469 .572 .687 .750 |
9.25 10.97 11.13 11.91 14.53 17.45 19.05 |
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for general information only.
3. Unless otherwise specified, tolerances are ±.010 (0.25 mm) on decimals and ±5° on angles.
4. Terminals need not be marked. Terminal identification is shown for reference purposes only.
FIGURE 1. Dimensions and configuration - Continued.
REQUIREMENTS:
For hardware detail specifications, see appendix of MIL-DTL-8834.
In the event of a conflict between the text of this specification and the references cited herein, the text of this specification shall take precedence.
Toggle seal test: Method I for 700 and 800 series. Method II for 200 and 300 series.
The switch shall be electrically and mechanically operative at the conclusion of the shock test with 2,000 foot pounds, except there can be transfer of the contact mechanism at all levels when tested in accordance with MIL- STD-202, method 207.
Terminals: Gold plated.
Weight: .0429 pound maximum (19.4 grams).
Strength of terminals: 5 pounds normal to the mounting plane and 1 pound in other planes. Altitude: 50,000 feet.
115 V ac 60 hertz electrical endurance tests are to be performed at room temperature and pressure.