MS21346F
TABLE I. Detail requirements. 1/ 2/
MS dash no. |
Locking comb. |
Circuit made between terminals as indicated with the toggle lever in these positions: 3/ |
Current capacity in amperes |
Life low current level switching 5 mV |
|||||||
Resistive load |
Inductive load |
||||||||||
Opposite keyway side 5/ |
Center positions |
Keyway side 5/ |
28 V dc |
115 Volts |
28 V dc |
115 Volts |
|||||
60 Hertz ac |
400 Hertz ac |
60 Hertz ac |
400 Hertz ac |
||||||||
-211 |
A, B, C, D, E |
ON 2-3 |
OFF |
ON 1-2 |
5 |
2 |
3 |
1 4/ |
1 |
2 |
25 µA 5/ |
-221 |
C, E |
NONE |
OFF |
||||||||
-231 |
ON 1-2 |
||||||||||
-241 |
J, B |
OFF |
NONE |
||||||||
-271 |
F, H |
MOM-ON 2-3 |
OFF |
MOM-ON 1-2 |
|||||||
-281 |
K |
NONE |
|||||||||
-311 |
G, K, L |
ON 2-3 |
|||||||||
-321 7/ 8/ |
L |
NONE |
ON 2-3 |
1/ For lever lock, part number shall consist of MS number, locking combination letter and dash number;
example part number: MS21346-B211 - Toggle sealed, on-off-on. Locked in center position.
2/ Without lever lock, part number shall consist of MS number and dash number. Example part number: MS21346-211-Toggle sealed on-off-on.
3/ Direction of movement of internal mechanism is opposite to the direction of the toggle movement.
4/ With time constant of .020 ± .002 seconds.
5/ Contact resistance not to exceed 50 ohms during life, low current level switching.
6/ Nonfunctional terminals shall not be supplied.
7/ Dielectric withstanding voltage: 1,200 V rms at sea level (center on circuits).
8/ Delayed action of the switch toggle lever may cause circuit to close on open before snap action mechanism trips.