MIL-PRF-24236/19L
TABLE II. Coarse high temperature setting to within 20°F.
Code
Temperature
Code
Temperature
Code
Temperature
(°F)
(°F)
(°F)
A-----
H-----
Q-----
-30
110
250
B-----
J-----
R-----
-10
130
270
C-----
K-----
S-----
10
150
290
D-----
L-----
T-----
30
170
310
E-----
M-----
U-----
50
190
330
F-----
N-----
V-----
70
210
350
G-----
P-----
W-----
90
230
385
TABLE III. Fine high temperature setting to within 5°F.
Code
Unit
A-------
0
B-------
+5
C-------
+10
D-------
+15
TABLE IV. Extent of qualification.
Configuration Number of samples required
Tests
Qualifies
Complete in accordance
All in accordance with table
1
with qualification inspection
of MIL-PRF-24236
of MIL-PRF-24236
All
2
Two each
3
Two each
Visual and mechanical
4
Two each
examination
5
Two each
Supersession data: See table V.
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business