MIL-PRF-24236/11J
TABLE V. Electrical ratings and endurance.
Altitude
Load
Life cycles
Sea level
70,000 feet
28 V
115 V, 60 Hz
28 V
(Ampere)
(Ampere)
(Ampere)
10,000
Resistive - - - - - - -
1.0
1.0
1.0
10,000
Inductive - - - - - - -
.5
.5
.5
10,000
Lamp - - - - - - - - -
.2
.2
.2
TABLE VI. Group submission.
Number of samples
Extent of
Configuration
Tests
required
approval
Visual and mechanical
1 and 2
3 each
examination, torque,
All 1/
vibration, shock, and seal
1/ Qualification is based upon prior approval to MIL-PRF-24236/19.
Supersession data: See table VII.
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.