MIL-PRF-22885/15E
REQUIREMENTS
Dimensions and configuration: See figures 1 and table II.
Complete switch shall consist of:
1 - Modular indicator light (MIL-PRF-22885/16).
1 - Switch assembly (MIL-PRF-22885/11).
4 - Color filters (MIL-PRF-22885/12), when specified (see table II).
4 - Lamps (T-1-3/4 midget-flange base incandescent type) not included, order separately.
Weight: 235 pound maximum.
Enclosure design: 1 (unsealed).
Vibration grade: 2 (10 to 500 Hz).
Display type: W (White backgrund).
Shock: (specified pulse): Method 213 of MIL-STD-202, test condition A (50g).
Thermal shock: Maximum temperature shall be -55 C.
Part number: M22885/15- (dash number from table II).
Qualification inspection: All applicants for qualification approval shall demonstrate that each of their items
conform to all the requirements specified in the applicable documents, singularly and in combination with
all other previously qualified items, regardless of manufacturer.
(a) When the basic sensitive switches are qualified to MIL-PRF-8805, switches shall be tested in
accordance with table I.
(b) When the basic sensitive switches are not qualified to MIL-PRF-8805, the switch type for which
qualification is sought, shall be submitted to the complete tests in accordance with table X of MIL-
PRF-22885. The sample switches submitted to the color and luminance test, group VIII shall also
be subjected to the color fade test in MIL-PRF-22885/12.
Group A inspection: Tests may be performed on individual MIL-PRF-22885/11 and MIL-PRF-22885/16
units prior to assembly as a MIL-PRF-15 unit, when applicable. Contact resistance may be performed on
individual MIL-PRF-8805/2 basic switches prior to assembly as MIL-PRF-22885/11 unit.
3