MIL-DTL-9395/41D
REQUIREMENTS:
Dimensions, configuration, and electrical schematic: See figure 1.
Weight: See figure 1.
Calibration: See tables I, II, III, IV, and IV.
Tolerance and maximum differential: See table I.
System pressure: 180 lbf/in2.
Proof pressure: 270 lbf/in2.
Burst pressure: 800 lbf/in2.
Electrical ratings:
Resistive: 1 ampere at 28 V dc.
Minimum current: 25,000 cycles.
Low level: 50,000 cycles
NOTE: Switches shall be subjected only to low level loads prior to delivery.
Seal:
Electrical chamber: Hermetic.
Pressure chamber: Hermetic.
Reference chamber: Unsealed.
Electrical connector: See figure 1.
Pressure port: See figure 1.
Media: Dry air, nitrogen, oxygen, Coolanol 25R, or equal.
High temperature (operating and nonoperating): B (+275°F).
Low temperature (operating and nonoperating): D (-65°F).
Altitude: C (70,000 feet).
Shock: C (100 G).
Vibration: S (test condition D, method 204 of MIL-STD-202), except 10 to 2,000 Hz, 20 G).
Supplemental nonoperating sinusoidal vibration:
Sweep time: 15 minutes.
Frequency range and amplitude: 50 through 81 Hz, .036 inch double amplitude; 81 through
210 Hz ±12 g; 210 through 298 Hz, .0053 inch double amplitude. 298 through 500 Hz, ±24 g.
Test duration: 15 minutes in each of three mutually perpendicular planes.
Life (mechanical): A (100,000 cycles).
Life (electrical): C (50,000 cycles).
Acceleration: C (8 g).
4