MIL-DTL-9395/32D
Explosion: Applicable.
QUALIFICATION:
Single submission: Restricted to switch submitted.
Group submission: See table V.
Part number: Part numbers shall be as follows:
Example:
M9395/32-
A
AD
AB
"M" prefix and specification sheet number
Configuration and pressure setting mode =
Code "A" of table I.
High-pressure setting = Code "A" of table II
(coarse value of 0 lbf/in2d) and code "D" of
table III (fine value of 1 1/2 ± 1/2 lbf/in2d).
Low-pressure setting = Code "A" of table II
(coarse value of 0 lbf/in2d) and code "B" of
table III (fine value of 1/2 ± 1/2 lbf/in2d).
Note: Design limitations (actuation values and tolerances, deadband and deactuation values and
tolerances) should be coordinated with the manufacturer(s) listed on the QPL for this specification sheet
before specifying a particular "M" number. The fact that operating characteristics can be coded does not
necessarily mean that it can be manufactured or acquired.
TABLE I. Codes for combinations of configurations and pressure setting modes.
Configuration 1
Configuration 2
Pressure
Electrical chamber Electrical chamber
High
High
setting
setting
Hermetic Unsealed Hermetic Unsealed
Code
A
D
G
K
At (or max) 1/ At (or min) 1/
Code
B
E
H
L
At (or max) 1/ Deadband 2/
Code
C
F
J
M
Deadband 2/
At (or min) 1/
Configuration 3
Configuration 4
Pressure setting mode
Electrical chamber Electrical chamber
High
Low
Hermetic Unsealed Hermetic Unsealed
setting
setting
Code
N
R
U
X
At (or max) 1/ At (or min) 1/
Code
P
S
V
Y
At (or max) 1/ Deadband 2/
Code
Q
T
W
Z
Deadband 2/
At (or min) 1/
1/ Setting values are designated by codes from tables II and III.
2/ Setting values are designated by codes from tables II and IV.
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business