MIL-DTL-9395/30H
2
TABLE III. Codes for pressure settings to within 25 lbf/in and tolerances.
Unit
Tolerance
2
0
+25 +50
+75
(lbf/in )
±25
Code
A
B
C
D
±50
Code
E
F
G
H
±75
Code
J
K
L
M
±100
Code
N
P
Q
R
±150
Code
S
T
U
V
±200
Code
W
X
Y
Z
±300
Code
1
2
3
4
±400
Code
5
6
7
8
Code
9
0
I
-
Min or Max
TABLE IV. Codes for differential pressure settings.
Differential
Differential
2
2
Code
value (lbf/in )
Code
value (lbf/in )
A
0
M
275
B
25
N
300
C
50
P
325
D
75
Q
350
E
100
R
375
F
125
S
400
G
150
T
425
H
175
U
450
J
200
V
475
K
225
W
500
L
250
TABLE V. Extent of qualification .
Number of
Part number
Tests
Qualifies
samples required
M9395/30-AADAA
1 each inductive
Complete per
-KADAA
1 each lamp
qualification
ALL
-14ZXV
1 each inductive
inspection of
configurations
-44ZXV
1 each lamp
MIL-DTL-9395
NOTES:
1. Pressure switches supplied to this specification sheet shall be designed to operate normally with
the system pump ripple at 3000 lbf/in at 0 to 700 Hz and average transient of 3000 ±500 lbf/in at
2
2
2
10 Hz peaking to 4050 lff/in .
2. Design limitations (actuation values and tolerances, deadband and deactuation values and
tolerances) should be coordinated with manufacturer(s) listed on the QPL for this spec sheet
before specifying a particular "M" number. The fact that operating characteristics can be coded
does not necessarily mean that it can be manufactured or procured.
14